Datalogic - CSME-03VU24-Y14 - Safety Relay Module
The Datalogic CSME-VU-Y is a cost-effective safety relay module designed for use with Datalogic’s SG and SE series light curtains that feature External Device Monitoring (EDM). This relay does not have internal monitoring; therefore, EDM control is mandatory. By utilizing the CSME relay, the OSSD outputs from the safety light curtain can be converted to potential-free relay contacts. With proper EDM connection, it maintains the same safety level as the connected safety light curtain.
Key Features:
• Compatibility: Designed to work seamlessly with Datalogic’s SG and SE series light curtains equipped with EDM functionality.
• Safety Outputs: Equipped with three normally open (NO) force-guided relay contacts and one normally closed (NC) contact for EDM.
• Compact Design: Housed in a polyamide PA . enclosure with a compact form factor, suitable for DIN rail mounting.
• LED Indicators: Features two LEDs for status indication, facilitating easy monitoring of operational status.
Technical Specifications:
• Supply Voltage: V DC (±%)
• Rated Power Consumption: < W (max)
• Start Power Consumption: < W (max)
• Safe Outputs: NO force-guided relay contacts + NC contact for EDM
• Maximum Switching Current: A
• Maximum Switching Voltage: / V AC, V DC
• Disconnection Time: ms
• Ingress Protection Class: IP (housing), IP (terminal block)
• Operating Temperature: – °C to + °C
• Material: Housing made of Polyamide PA . class V (UL)
• Dimensions (L x H x D): . mm x . mm x . mm
• Weight: Approximately g
• Mechanical Endurance: > million operations
• Electrical Endurance: > , operations
• Standard Conformity: Complies with EN -, EN , EN , EN , EN ISO -, EN ISO -, EN , EN , EN --, EN --, EN -, EN -, EN -, UL , CSA C. No. -
• Approvals: CE-marking, UL file E
Applications:
• Safety Light Curtains: Ideal for converting OSSD outputs from safety light curtains to potential-free relay contacts in industrial safety applications.
• Machine Safety Systems: Enhances safety in machinery by providing reliable relay outputs for safety-related controls.